Home › Free guides › Wells

Drilled and Dug Wells: Siting, Construction and Yield

Water  13 min read

A well is the most common water source on rural property in Canada and the northern United States, and the most expensive single piece of off-grid infrastructure to get wrong. This guide covers the kinds of wells, where the rules let you put one, how drilled and dug wells are built and sealed, how to read a yield test, how to work out whether a well can meet household peak demand, what to do with a low-yield well, how to look after the wellhead, and how old wells must be decommissioned.

Types of wells

Drilled wells

A drilled well is a borehole made by a drilling rig, lined with steel or plastic casing through soil and loose material and usually into bedrock. Below the casing the hole may stay open in rock, or a screen may be set in a sand or gravel aquifer. Household wells are commonly drilled with 150 mm (6 in) casing. Because water comes from depth and the casing is sealed at the surface, a properly built drilled well is the best-protected type.

Dug and bored wells

A dug well is a wide, shallow excavation, usually lined with concrete tiles, that collects water from near-surface soil. A bored well is similar but made with an auger. They store a large volume in the well itself, which helps where the soil yields water slowly, but they draw from shallow water that is easily affected by runoff, septic effluent and drought. Ontario's regulation treats them as "any other well" and requires larger separation distances than for deep-cased wells.

Driven and jetted point wells

A point well is a narrow pipe with a screened tip, driven or jetted into shallow sand or gravel. It is cheap and suits seasonal cabins on sandy ground, but yield is limited and it depends on a suction pump.

FeatureDrilled wellDug or bored wellPoint well
Water sourceDeep bedrock or confined aquiferShallow soil waterShallow sand or gravel
Storage in the wellSmallLargeVery small
Contamination riskLowestHighestHigh
Usual pumpSubmersibleJet or submersibleShallow-well jet

Who may build a well

Well construction is regulated in every province and state, and in most places only a licensed or registered contractor may build one.

  • British Columbia: under the Groundwater Protection Regulation, wells must be constructed by a qualified well driller holding a certificate issued under the regulation, who must be at least 19 years old and carry the identification card issued by the comptroller. Well pump installers are certified separately. The driller must submit a well construction report.
  • Ontario: the Wells Regulation (R.R.O. 1990, Reg. 903) under the Ontario Water Resources Act governs construction. The contractor must deliver the well record to the purchaser and landowner within 14 days and forward it to the ministry within 30 days, and must give the purchaser a water sample of at least 1 L.
  • Other provinces and states have their own licensing and reporting rules. Check the contractor's licence with the regulator before work starts.

Well records are valuable before you drill. Ask the provincial or state regulator for records of nearby wells, which show depth, casing length, static water level and tested yield; several provinces publish them online. Records for neighbouring properties are the best available guide to what depth and yield to expect, and whether nearby wells report salty, sulphurous or iron-rich water.

Siting a well

Separation distances

Ontario's Wells Regulation sets minimum distances between a new well and sources of contamination, with smaller distances for wells with watertight casing to a depth of at least 6 m (19.7 ft):

SourceWell with watertight casing to at least 6 mAny other well
Septic tank or other treatment unit15 m (50 ft)15 m (50 ft)
Holding tank15 m (50 ft)15 m (50 ft)
Distribution pipe in a leaching or filter bed15 m (50 ft)30 m (100 ft)
Earth pit privy15 m (50 ft)30 m (100 ft)
Privy vault or pail privy10 m (33 ft)15 m (50 ft)
Greywater system10 m (33 ft)15 m (50 ft)
Cesspool30 m (100 ft)60 m (200 ft)

These distances also apply to septic systems and privies that have a building permit but are not yet built. Other sources, such as manure piles, barns, fuel tanks and fertilizer storage, are assessed case by case.

In British Columbia, a new water supply well must be at least 15 m from an existing water supply well unless the existing well is out of use, and nothing may be stored within 3 m (10 ft) of the wellhead. Setbacks between wells and septic systems in BC are set under the sewerage system rules; your authorized onsite practitioner and driller will know the current distances. Other provinces and states set their own; check before placing either the well or the septic field, since each limits where the other can go.

Good practice beyond the minimums

  • Put the well on ground higher than its immediate surroundings, as Ontario requires, so surface water drains away from it.
  • Locate it upslope, and up the direction of groundwater flow, from septic fields, barns, fuel tanks and roads.
  • Increase distances where the aquifer is shallow, where bedrock is fractured with thin soil over it, or where the well is downslope of a contamination source.
  • Leave a clear path and overhead room for a pump hoist truck, away from power lines.
  • Never place it under a deck, addition or driveway. Ontario requires the well to be accessible for cleaning, treatment, repair, testing and inspection at all times.

How a drilled well is built and sealed

The casing keeps the borehole open and keeps shallow water out. What protects the well from surface contamination is the seal in the annular space, the gap between the outside of the casing and the borehole wall. Without it, surface water can run down the outside of the casing straight into the aquifer.

Surface seal rules in BC

  • A continuous, permanent surface seal must fill the annular space, at least 2.54 cm (1 in) thick.
  • For a water supply well, the seal must be at least 5 m (16.4 ft) long, or as long as possible in a shallower well.
  • Where bedrock is at or within 5 m of the surface, the seal must extend at least 1 m (3.3 ft) into competent bedrock.
  • The sealant must be less permeable than the surrounding ground and non-toxic; bentonite clay and cement grout are common.

Casing height

The top of the casing must stand above the ground so surface water and snowmelt cannot flow in.

  • Ontario: at least 40 cm (16 in) above the highest ground within 3 m (10 ft), after the ground is mounded for drainage, and at least 15 cm (6 in) above any floor built around the casing.
  • British Columbia: at least 0.3 m (12 in) above the adjacent ground, or above the floor of a pump house, sump or well pit.

Mound the ground around the casing so water drains away and cannot pond. Never bury a wellhead or cut the casing below grade to suit landscaping.

Well caps and identification

BC requires a securely attached cap that keeps out surface water, floodwater, debris, people and animals. A commercially made, vermin-proof cap with a screened vent is the usual choice. Ontario wells built since October 2003 carry a steel well tag, about the size of a credit card, attached to the casing where the cap and equipment do not hide it. Keep the tag number with the well record; it links the well to its construction details.

Pitless adapters

A pitless adapter is a fitting on the side of the casing, below frost depth, that lets the water line leave the well underground while the casing continues up to its full height above grade. It replaces the old practice of building a well pit, a below-ground chamber that collected surface water and was a frequent source of contamination.

Dug wells

Many older rural properties rely on a dug well. If you have one, or must build one where no aquifer can be drilled, the protection measures are the same in principle as for a drilled well, applied to a much larger opening:

  • a solid, watertight cover, which Ontario requires, sealed to the top of the well tiles and secured against children and animals;
  • tile joints sealed in the upper part of the well, so shallow seepage does not enter near the top;
  • the well top raised above grade and the ground mounded so runoff drains away;
  • separation distances at the larger "any other well" values in the table above;
  • no garden, lawn fertilizer, road salt or animal pen near it.

Dug wells respond quickly to rainfall and drought. Expect the water level to fall in late summer and in dry years, and test the water more often than a drilled well, since bacteria and nitrate from the surface reach it more easily. Our guide to water treatment and testing covers testing schedules.

Yield testing

A yield test shows how much water the well can deliver. In Ontario, the contractor must pump the new well continuously at a steady rate for at least 1 hour with a pump, not a bailer or compressed air, record the static water level before pumping, record water levels at set intervals during pumping, and then record recovery for at least another hour after the pump stops.

TermMeaning
Static water level (SWL)Depth to water before pumping starts
Pumping water level (PWL)Depth to water during pumping
DrawdownPWL − SWL
RecoveryHow quickly the level rises back after the pump stops
Specific capacityPumping rate ÷ drawdown, in L/min per metre

Ontario's example: pumping 45 L/min (10 imperial gal/min) with 6 m (20 ft) of drawdown gives a specific capacity of 45 ÷ 6 = 7.5 L/min per metre.

Ontario's Wells Regulation sets no minimum yield for a household well; lenders, insurers and some municipalities set their own, so ask before buying a property. A 1-hour test is short. It shows whether the well can deliver a given rate for an hour, not whether it can sustain that rate through a dry summer. Where yield is marginal, ask the contractor for a longer test, and watch whether the water level was still falling when the test ended.

Worked example: reading a well record

A well record shows 150 mm casing, total depth 60 m (197 ft), static water level 15 m (49 ft), tested at 20 L/min (4.4 imperial gal/min) for 1 hour with a pumping water level of 27 m (89 ft).

Drawdown: 27 − 15 = 12 m. Specific capacity: 20 ÷ 12 = 1.7 L/min per metre.

With the pump intake at 55 m, the available drawdown is 55 − 15 = 40 m. Pumping at 20 L/min used only 12 m of it, so there is room to spare at that rate. Do not assume the well could deliver 1.7 × 40 = 67 L/min: drawdown usually grows faster than the pumping rate, and the test said nothing about longer pumping. Choose a pump rated slightly below the tested yield.

Can the well meet peak demand?

Households use water unevenly. Penn State Extension notes that peak demand periods usually last 30 minutes to 2 hours and that a system should meet peak demand for at least 2 hours. A family of four without water-saving fixtures can use more than 300 US gal (1,136 L) in a 2-hour morning peak.

During a peak, water comes from three places: the well's yield, the water stored in the casing above the pump, and the usable volume of the pressure tank. A 150 mm (6 in) casing holds about 18.2 L per metre (1.47 US gal per foot).

Worked example: a 2-hour peak from a moderate well

The well from the previous example yields 20 L/min. Over 2 hours: 20 × 120 = 2,400 L. That alone exceeds the 1,136 L peak, so the well is adequate.

A poorer well yields 2 L/min with the same casing, static level at 15 m and pump intake at 55 m:

  • Yield over 2 hours: 2 × 120 = 240 L
  • Water stored in the casing between static level and pump intake: 40 m × 18.2 = 728 L
  • Usable volume in a 160 L pressure tank: about 40 L

Total: 240 + 728 + 40 = 1,008 L, short of 1,136 L. The household would run the well down to the pump during a heavy peak, and the pump would draw air or shut off on its dry-run protection. The well still produces 2 × 1,440 = 2,880 L per day, more than double the daily use of most households; the problem is the rate, not the daily total.

Living with a low-yield well

A well that produces enough water over 24 hours but not enough during a peak can be made to work.

  • Add storage. Pump slowly from the well into a cistern or storage tank, and use a second pump to pressurize the house from the tank. Penn State's rule of thumb for homes is 100 US gal (about 380 L) of storage per person, so four people need about 1,500 L (400 US gal). The well pump then runs at a low rate for long periods, which suits a small solar-powered pump.
  • Protect the pump. Fit a low-water cut-off or a pump controller with dry-run protection so the pump stops before the water level reaches the intake.
  • Spread demand. Spread laundry through the week and avoid running showers, washer and dishwasher at once. Low-flush toilets, low-flow showerheads and a front-loading washer cut peak use.
  • Do not rely on a bigger pressure tank. Only 20 to 30% of a pressure tank's volume is usable, so even a large tank adds little.
  • Deepen with care. Drilling deeper adds casing storage (about 18 L per metre in a 150 mm well) and may reach new water-bearing fractures, but water quality can change at depth. Ask the contractor about the options for your geology before paying for more footage.

Looking after the wellhead

  • Inspect the wellhead at least once a year and after floods: cap secure and undamaged, vent screen intact, casing uncracked, ground still sloping away.
  • Keep the area within 3 m (10 ft) clear of stored materials, fuel, fertilizer, pesticides and vehicles. BC prohibits storing foreign matter in that zone.
  • Keep the well record, tag number, pump details and service records together.
  • Test the water at least once a year for bacteria, after any work on the well, and whenever taste, colour or odour changes.
  • Shock-chlorinate after any well or pump work, as described in our water systems guide.

Decommissioning old wells

An abandoned well is a direct path for surface contamination into the aquifer, and an open dug well is a fall hazard. Most rural properties with a long history have one or more old dug wells or unused drilled wells.

Under BC's regulation, a well that has not been in service for 5 years is treated as needing decommissioning. Decommissioning means removing the pump and equipment where practicable, filling the well with sealant and backfill so that each aquifer is sealed off, and placing a closure plug of sealant at the top, at least 5 m (16.4 ft) long for a water supply well. In uncased sections, sealant layers must be at least 1 m thick with no more than 6 m of backfill between them. Most decommissioning must be done by a qualified well driller or well pump installer; any person may decommission a well up to 5 m deep, or an excavated (dug) well up to 15 m deep, provided it is not a flowing artesian well.

Ontario's Wells Regulation also sets requirements for abandoning wells, and other provinces and states have their own rules. Report decommissioned wells to the regulator where required, so the well records stay accurate for the next owner.

Key points

  • Drilled wells with sealed casing are the best-protected water source; dug and point wells draw shallow water and need larger separation distances.
  • Wells must be built by licensed or registered contractors who file a well record. Search existing well records for nearby properties before drilling.
  • Ontario requires 15 m (50 ft) between a deep-cased drilled well and a septic tank or leaching bed, and 30 m (100 ft) between other wells and a leaching bed.
  • The annular seal stops surface water reaching the aquifer: in BC at least 2.54 cm thick and 5 m long. Casing must stand at least 40 cm above grade in Ontario and 0.3 m in BC.
  • Specific capacity = pumping rate ÷ drawdown. A 1-hour test does not prove long-term yield.
  • Check that yield, casing storage (18.2 L per metre of 150 mm casing) and pressure tank together meet a 2-hour peak; add a storage tank if they do not.
  • Keep the wellhead accessible, capped and clear, and have unused wells properly decommissioned. Never enter a dug well.

This guide is general information. Codes, permits and safety requirements vary by province, state and municipality. Check local rules and use a qualified professional for electrical, gas, chimney and septic work where required.

The Comprehensive Off-Grid Manual

Every off-grid system in one manual, with worked examples, checklists and northern-climate detail.