Rainwater Harvesting for Household Use

Water  13 min read

Roof rainwater can supply toilets, laundry and gardens on almost any property, and with proper treatment it can supply a whole household where wells are poor or salty. This guide covers the standards and rules that apply in Canada and the United States, a month-by-month water balance you can repeat with your own climate data, gutter and pipe sizing, tank details from inlet to overflow, separating rainwater from drinking water, the treatment benchmarks for potable use, protecting the system in winter, and a maintenance schedule.

Standards and rules

CSA B805/ICC 805

CSA B805/ICC 805, Rainwater Harvesting Systems, was written by a joint committee of CSA Group and the International Code Council. The 2018 edition covers the design, materials, installation and operation of systems for both potable and non-potable uses, with roof runoff and stormwater as sources; stormwater is not covered for potable use. A current edition, CSA B805:22/ICC 805:2022, is listed by the Standards Council of Canada. The standard:

  • requires a water safety plan for every system, assessing the site, risks to source water quality, how each component performs, and the risk at each end use;
  • groups uses into four end-use tiers according to exposure by drinking, breathing spray and skin contact, from low-exposure uses such as toilet flushing up to drinking, food preparation and bathing;
  • sets treatment requirements and water quality checks for each tier, with separate groupings for single-family homes and for multi-family, commercial and public buildings.

The standard is voluntary unless a code or authority adopts it. It is the most complete reference available for designing a household rainwater system in Canada or the US.

Building and plumbing codes

Local codes and bylaws set the rules for non-potable rainwater uses such as toilet flushing and subsurface irrigation, including pipe marking, backflow protection and tank construction. Calgary's guidelines for internal non-potable rainwater use, for example, reference the National Plumbing Code, the CSA B128 series for non-potable water systems, CSA B64.10 for backflow preventers, CSA B66 for prefabricated underground tanks and the Canadian Electrical Code. Calgary requires permits before work starts; expect a permit to be needed wherever a rainwater system connects to building plumbing, and check with your local building authority before buying a tank.

Rainwater as drinking water

Regulation of private drinking water varies. In British Columbia, the provincial small water systems guidebook states that a single-family residence on its own system is exempt from most requirements of the Drinking Water Protection Act, and that the property owner is responsible for the safety of the water. A system that serves more than one household can fall under the Act and its approval and monitoring requirements. Other provinces and states have their own thresholds. Where there is no regulatory oversight, the CSA B805 tiers and the treatment benchmarks below are the standard to work to.

Sizing with a monthly water balance

Calgary's guidelines use this formula for the water a roof collects:

Collected volume (L) = roof area (m²) × collection efficiency × (rainfall (mm) − wetting factor (mm))

The wetting factor is rain that wets the roof without running off, subtracted for each rainfall event. The guidelines give 0.25 mm for metal roofs, 0.5 mm for asphalt shingle and fibreglass, and 1.5 mm for built-up and rubber flat roofs, each with an 80% collection efficiency. Light showers below the wetting factor produce nothing, which is why a roof in a climate of frequent drizzle collects less than its annual rainfall suggests.

A monthly water balance compares collection with demand month by month and tracks what is left in the tank. Use the climate normals for the nearest weather station: monthly precipitation, the number of days with measurable rain, and the months when precipitation falls as snow. Snow collects on the roof and melts gradually or slides off, so count winter months as producing little or nothing in most of Canada.

Worked example: a seasonal cabin on a 100 m² metal roof

A cabin is used from April to November. The roof footprint is 100 m² (1,076 sq ft), metal. The rainfall figures below are an example profile; substitute the normals for your own location. Collection in each month = 100 × 0.8 × (rainfall − 0.25 × rain days).

MonthRainfallRain daysCollectedDemand at 100 L/daySurplus
April55 mm94,220 L3,000 L1,220 L
May65 mm105,000 L3,100 L1,900 L
June75 mm105,800 L3,000 L2,800 L
July55 mm84,240 L3,100 L1,140 L
August45 mm73,460 L3,100 L360 L
September60 mm84,640 L3,000 L1,640 L
October70 mm105,400 L3,100 L2,300 L
November35 mm62,680 L3,000 L−320 L

At 100 L per day, every month but November produces a surplus. The tank does not need to carry water from one month to the next; it needs to cover the longest gap between useful rains. If records show gaps of up to 3 weeks without rain, the tank should hold 21 × 100 = 2,100 L plus a margin, so a 3,000 L (790 US gal) tank is reasonable. Monthly totals hide dry spells inside a month, so check daily records for the longest dry runs.

At 150 L per day, the season's demand is 244 days × 150 = 36,600 L, while the roof collects 35,440 L over the same months. No tank size fixes this: the roof is too small. The cabin needs about 100 × 36,600 ÷ 35,440 = 103 m² of roof, plus a margin for dry years, or lower demand, for example from a composting toilet.

For a household using rainwater through the winter, the same method shows the scale of the problem: months of snow produce almost nothing, so the tank must hold the whole winter's demand, or another source must take over. A household using 150 L per day through four snow months needs about 150 × 120 = 18,000 L of stored water at freeze-up. Our water systems guide covers sizing for a summer dry period, which is the controlling case on the Pacific coast.

Gutters, downspouts and pipes

Calgary's guidelines give these sizes for residential systems:

  • Eavestroughs: 125 mm (5 in) K-style, sloped at 0.5 to 2%.
  • Downspouts: 50 × 75 mm or 75 × 75 mm (2 × 3 in or 3 × 3 in).
  • Conveyance pipe to the tank: at least 100 mm (4 in) for roofs under 200 m², and 150 mm (6 in) for roofs of 200 to 550 m².
  • Pipe slope: 0.5% minimum, 2% as the industry standard, more where possible.
  • Buried pipe: warning tape and tracer wire at least 300 mm (12 in) above it.

Fit leaf guards or screens on gutters and a debris excluder at each downspout, then a first-flush diverter before the tank, as described in our water systems guide. CSA B805 includes the debris excluder, first-flush diverter, overflow and vent among the standard components of a system.

Roof materials

For drinking water, the roof is part of the treatment system. Metal roofing with a finish its maker states is suitable for potable water collection is the usual choice. Avoid roofs with treated wood shakes, lead flashing, old asbestos-cement products, copper, or zinc moss-control strips; our water systems guide covers these. Keep overhanging branches cut back, since they drop debris and give birds and rodents a perch above the roof.

Tank details

A tank for rainwater needs more than an inlet and a tap. Points from Calgary's guidelines and from good practice:

  • Access: an access hatch at least 450 mm (18 in) across, with 600 mm (24 in) or larger recommended. Calgary requires any opening over 150 mm (6 in) to be lockable.
  • Calmed inlet: bring the inflow to the bottom of the tank through a pipe ending in an upturned elbow or diffuser, so incoming water does not stir up settled sediment.
  • Dead space: Calgary's guidelines allow about 100 to 150 mm (4 to 6 in) at the bottom for sediment. Do not count it as usable storage.
  • Floating extraction: draw water through a floating intake just below the surface, where the water is cleanest, above both the sediment and any floating debris.
  • Overflow: at least the same size as the inlet, exiting 50 mm (2 in) below the inlet pipe, screened at its end, and discharging well away from foundations, septic fields and wells.
  • Screening: insect and vermin screens on every opening above grade, including vents and the overflow outlet. An unscreened tank breeds mosquitoes.
  • Material: opaque, rated for potable water where the water will be drunk, and rated for burial if buried. Calgary's guidelines reference CSA B66 for prefabricated underground tanks.
  • Base: 1,000 L of water weighs 1 tonne; set the tank on a level, compacted base or slab designed for the full load.

Keeping rainwater and drinking water separate

Where rainwater serves only some uses, such as toilets and irrigation, while a well or other source supplies drinking water, the two systems must never mix. Calgary's guidelines set out typical requirements:

  • Permitted uses for untreated non-potable rainwater: toilets, urinals and subsurface irrigation. Prohibited: drinking, kitchen and bathroom sinks, showers and baths, laundry, dishwashers, hose bibs, and spray irrigation.
  • Marking: purple pipe for non-potable lines, and a sign at least 100 × 100 mm reading "Warning: Non-potable Water – Do Not Drink" at outlets.
  • Separation: non-potable pipe at least 100 mm from potable pipe above grade and 300 mm below grade.
  • Top-up: where potable water tops up the rainwater tank in dry weather, it must enter through an air gap of at least 25 mm (1 in), or twice the top-up pipe diameter, above the highest water level, and a backflow preventer is needed on the main supply.

Outdoor uses such as garden watering can be supplied from a separate tank with its own pump and no connection to the house plumbing, which avoids most of these requirements. Check what your local authority allows.

Choosing where the tank goes

Tank location affects cost, water quality and whether the system works in winter.

  • Below the roof, above the use: a tank lower than the gutters fills by gravity. If it also sits higher than the taps it serves, it can supply them by gravity; each metre of height gives about 9.8 kPa (1.4 psi), so a garden tank 2 m above the beds delivers about 20 kPa (2.8 psi), enough for drip irrigation but not for sprinklers. Our pumps guide covers gravity supply in more detail.
  • Buried: keeps water cool and dark, which limits algae and bacterial growth, and protects it from freezing if set below frost depth. It costs more to excavate and needs a pump.
  • Indoors: stays in service all winter and is easy to inspect, but takes floor space and needs a floor built for the weight.
  • Above ground outdoors: cheapest, but seasonal in most of Canada, exposed to sun and damage, and must be opaque to stop algae.

Keep every tank away from septic fields, fuel tanks and livestock areas, on ground that drains away from it, with a route for a service vehicle if the tank will ever need pumping out or replacing.

Garden-only systems

The simplest rainwater system feeds the garden from one or more tanks at downspouts, with no connection to the house. A garden-only system needs no treatment, though local rules may still apply, and it still needs screens against mosquitoes, a secure lid, an overflow directed away from the foundation, and a place to drain it before freeze-up. Linking several small tanks at their bases increases storage without a large tank. Because the garden's demand peaks in the driest weeks, run the same monthly balance before buying tanks; the example above shows how quickly demand can exceed what a roof collects.

Treating rainwater for drinking

Roof water carries bacteria, viruses and protozoa from bird and animal droppings, so it must be treated before drinking, cooking, brushing teeth or bathing. BC's treatment objectives for small water systems on surface water give a useful benchmark for what treatment should achieve:

  • 99.99% (4-log) reduction or inactivation of enteric viruses;
  • 99.9% (3-log) reduction or inactivation of Giardia and Cryptosporidium;
  • two treatment processes for surface water sources;
  • turbidity of 1.0 NTU or less;
  • no detectable E. coli, fecal coliforms or total coliforms.

BC's guidebook also notes that water above 5.0 NTU is visibly cloudy and can shelter microorganisms from disinfection.

A typical household treatment train is:

  1. Source protection: clean roof and gutters, screens, first-flush diverter, calmed inlet and floating extraction.
  2. Sediment filtration after the pressure pump, often in two stages from coarse to fine.
  3. Activated carbon for taste, odour and colour from organic matter, if needed.
  4. Disinfection with a UV unit certified to NSF/ANSI 55 Class A, sized for the full flow rate, with an alarm or shut-off if the lamp fails. Chlorination is the alternative, and leaves a residual.

Rainwater is very soft and slightly acidic, so it can dissolve copper and brass in plumbing. Test the treated water for pH, copper and lead as well as bacteria. Our guide to water treatment and testing covers sampling, certification standards and testing schedules.

Winter

Calgary's guidelines put frost depth there at about 1.83 m (6 ft) and give extruded polystyrene insulation thicknesses for pipes buried above that depth:

Burial depth to backfillInsulation thickness (XPS)
0.6 m (2 ft) or less100 mm (4 in)
0.9 m (3 ft) or less90 mm (3.5 in)
1.2 m (4 ft) or less75 mm (3 in)
1.5 m (5 ft) or less65 mm (2.5 in)
1.8 m (6 ft) or less50 mm (2 in)
2.1 m (7 ft) or less40 mm (1.5 in)

These values are for Calgary's climate; colder sites need more and milder sites less. The guidelines prefer insulation over heat tracing, which works but uses a lot of energy, and require above-ground tanks to be drained and taken out of service for winter.

  • Buried tanks below frost depth, or tanks inside heated space, can stay in service. An indoor tank adds weight and humidity to the building; place it on a floor designed for the load.
  • Gutters and downspouts freeze and fill with ice. Disconnect the downspout from the tank inlet in late fall, or fit a seasonal diverter, so meltwater and ice do not split pipes.
  • First-flush diverters hold water and freeze; drain them before freeze-up.
  • Drain above-ground pumps, filters and UV chambers if they are not in heated space.

Maintenance schedule

Calgary's guidelines set these intervals for a rainwater system:

ComponentInterval
Roof and eavestroughsEvery 6 months
First-flush and other pre-storage devicesAfter several rainfall events, or as the maker specifies
Post-storage filtersEvery 3 months, or as the maker specifies
Top-up systemEvery 6 months
Tank interiorYearly
Pump and pressure systemYearly
Backflow preventer and air gapYearly
Above-grade discharge (overflow)Yearly

Add to this, for a potable system: replace the UV lamp on the maker's schedule, test for bacteria on the schedule in our water treatment guide, and test after any long dry period, roof work, or sign of animals in the gutters or tank. Keep a log of rainfall, tank levels and maintenance; after a year it gives a better sizing basis than any climate table.

Costs

Calgary's 2019 guidelines estimated storage at about $0.30 to $0.75 per litre and a complete internal non-potable system at about $6,000 to $14,000. Costs vary widely with tank material, whether the tank is buried, pumping and treatment, and distance from suppliers; get quotes for your own design. A potable system adds treatment equipment and testing. The guidelines' rule for tank size is to keep increasing the size only while each extra 1,000 L of storage adds at least 2.5% to the water saved.

Key points

  • CSA B805/ICC 805 covers potable and non-potable rainwater systems and requires a water safety plan matched to each end use.
  • Collected volume = roof area × 0.8 × (rainfall − wetting factor), with a wetting factor of 0.25 mm per event for metal roofs.
  • Run a month-by-month balance from local climate normals. If seasonal collection is less than seasonal demand, a larger tank will not help; a larger roof or lower demand will.
  • Count snow months as producing little; a household using rainwater all winter must store the whole winter's demand.
  • Fit screens, a calmed inlet, floating extraction, a screened overflow at least as large as the inlet, and a lockable hatch.
  • Keep non-potable rainwater separate: purple pipe, warning signs, an air gap on top-up, and backflow protection.
  • Treat drinking rainwater to remove 99.99% of viruses and 99.9% of protozoa, with turbidity of 1 NTU or less and no detectable coliforms.
  • Insulate buried lines, drain above-ground tanks and diverters for winter, and follow a regular maintenance schedule.

This guide is general information. Codes, permits and safety requirements vary by province, state and municipality. Check local rules and use a qualified professional for electrical, gas, chimney and septic work where required.