A septic system is the standard way to treat household wastewater on a rural property with a flush toilet and a pressurized water supply. It depends on the right soil, the right size and regular care. A system that is too small, built on the wrong ground or never pumped backs up into the house and contaminates wells and lakes. This guide explains how a septic system works, the main system types, how regulators size the tank and the leaching bed, the clearances and soil depths that protect water supplies, who is allowed to design and build a system, and how to look after one for decades of service.
How a septic system works
A conventional system has two parts: a watertight tank and a soil-based dispersal area, usually called the leaching bed, drainfield or tile bed.
The tank
All household wastewater flows by gravity into the tank. It sits there long enough for solids to separate into three layers:
- Scum: oil, grease and light solids float to the top.
- Sludge: heavier solids settle to the bottom, where bacteria slowly digest part of them.
- Clarified effluent: the liquid layer between them flows out through a baffle or outlet tee to the leaching bed.
A tank removes solids. It does not make the water safe. Effluent leaving a septic tank still carries bacteria, viruses and nutrients. Ontario requires two compartments, with about two-thirds of the volume in the first, so that solids that escape the first chamber settle in the second.
The leaching bed
Effluent runs into perforated distribution pipes or plastic leaching chambers laid in trenches or a bed of stone or sand. It seeps into the soil below, where a biological mat and the unsaturated soil filter and treat it. That is why regulators require a minimum depth of suitable, unsaturated soil under every leaching bed.
Common system types
The right type depends on how fast the soil absorbs water, its depth to rock or the seasonal high water table, and the space available.
| System | How it works | Suits |
|---|---|---|
| Conventional absorption trenches | Gravity flow from the tank to perforated pipe or leaching chambers in parallel stone trenches | Deep, moderately permeable native soil |
| Shallow buried trenches | Narrow trenches 300 to 600 mm (12 to 24 in) deep and 2 m (79 in) apart | Sites where a shallower trench bottom is needed to keep the required soil depth beneath it |
| Filter bed | A single bed of imported filter sand with distribution pipes in stone on top | Smaller lots, or soils too slow for trenches of practical length |
| Raised bed or mound | The bed is built up above the original ground with imported fill to create the required depth of unsaturated soil | High water table, shallow bedrock, very slow or very fast soils |
| Pressure distribution | A pump chamber doses effluent through small-diameter pipes so the whole bed is loaded evenly | Mounds, sloping sites, and any bed uphill of the tank |
| Advanced treatment unit | Aerobic, media or other treatment after the tank produces cleaner effluent before dispersal | Difficult sites, smaller dispersal areas, sensitive shorelines |
| Holding tank | Watertight tank with no discharge; pumped out and hauled away | Last resort where no dispersal is possible |
Treatment levels
British Columbia's Sewerage System Regulation defines three effluent treatment levels, a useful way to compare systems anywhere:
- Type 1: treatment by septic tank only.
- Type 2: effluent that consistently has less than 45 mg/L of total suspended solids (TSS) and less than 45 mg/L of five-day biochemical oxygen demand (BOD).
- Type 3: effluent that consistently has less than 10 mg/L of TSS and less than 10 mg/L of BOD, with a median fecal coliform density below 400 colony-forming units per 100 mL.
Treatment units with pumps or blowers use electricity and need servicing. On an off-grid property, get the unit's continuous power draw and add it to your electrical load audit before choosing one.
Holding tanks
A holding tank is expensive to operate because every litre used must be hauled away. In BC, building a holding tank needs a permit from a health officer, which costs $400 and requires a maintenance plan with the application.
Site assessment
Every design starts with the soil. A designer digs test pits to see soil layers, depth to bedrock and signs of a seasonal high water table, such as mottled or grey soil. Soil permeability is measured or estimated as a percolation time, called the T-time in Ontario: the time in minutes for the water level in a test hole to drop 1 cm.
- Low T-time (coarse sand): water can drain too quickly to be treated before it reaches groundwater.
- Moderate T-time (loams and fine sands): the best conditions for conventional trenches.
- High T-time (silts and clays): the bed must be much larger, or built in imported sand.
In Ontario, conventional trenches cannot be used where the T-time is 50 or greater. The bottom of an absorption trench must sit at least 900 mm (35 in) above the high groundwater table, rock, or soil with a percolation time over 50 minutes. Where native soil cannot meet that, the bed is raised with imported fill.
Clearances
Separation distances protect wells, surface water and buildings. The Ontario Building Code (Tables 8.2.1.6.A and 8.2.1.6.B) sets the following minimum horizontal clearances for a Class 4 system. Other provinces and states use different figures, and local rules or poor soil can increase them.
| Feature | From the septic tank | From the leaching bed (distribution pipe) |
|---|---|---|
| Structure | 1.5 m (5 ft) | 5 m (16 ft) |
| Well with watertight casing to at least 6 m (20 ft) depth | 15 m (49 ft) | 15 m (49 ft) |
| Any other well | 15 m (49 ft) | 30 m (98 ft) |
| Lake, river, stream, pond, reservoir or spring | 15 m (49 ft) | 15 m (49 ft) |
| Property line | 3 m (10 ft) | 3 m (10 ft) |
Leaching bed clearances are measured to the centreline of the outermost distribution pipe or leaching chamber.
How a system is sized
Regulators size systems from a daily design flow, a deliberately generous estimate of the most the house could produce on a busy day, not its average use. The US EPA's homeowner guide puts average indoor use in a single-family home at nearly 70 US gal (265 L) per person per day, well below most design flows.
Ontario's method is a clear example. It starts with a base flow set by the number of bedrooms, because bedrooms predict how many people a house can hold over its life.
| Bedrooms | Base daily design flow |
|---|---|
| 1 | 750 L (198 US gal) |
| 2 | 1,100 L (291 US gal) |
| 3 | 1,600 L (423 US gal) |
| 4 | 2,000 L (528 US gal) |
| 5 | 2,500 L (660 US gal) |
One additional flow is then added, using only the largest of these that applies:
- 500 L for each bedroom over five;
- 100 L for each 10 m² of floor area over 200 m² up to 400 m², with smaller amounts per 10 m² above that;
- 50 L for each fixture unit over 20.
Fixture units measure plumbing load. Ontario's worksheet values include: bath group (toilet, sink, and tub or shower in one room) 6.0; flush-tank toilet 4.0; wash basin 1.5; shower 1.5; bathtub 1.5; kitchen sink 1.5; domestic washing machine 1.5; dishwasher not connected to a sink 1.0; floor drain 3.0.
Tank size
For a house, Ontario requires a septic tank with a working capacity of at least twice the daily design flow, and never less than 3,600 L (951 US gal). Other occupancies use three times the daily flow.
Trench length
For conventional absorption trenches, the total length of distribution pipe is:
Trench length (m) = Q × T ÷ 200
where Q is the daily design flow in litres and T is the percolation time in minutes per centimetre. Trenches using Type II leaching chambers use Q × T ÷ 300.
Each trench run must be about equal in length and no longer than 30 m (98 ft). Trenches are 500 to 1,000 mm (20 to 39 in) wide and 600 to 900 mm (24 to 35 in) deep, spaced 1.6 m (63 in) centre to centre with pipe or Type I chambers, or 2.4 m (94 in) with Type II chambers.
Worked example: a three-bedroom house on loam
A 150 m² (1,615 sq ft) three-bedroom house has one full bathroom, a powder room with toilet and basin, a kitchen sink, a dishwasher and a washing machine. The soil has a T-time of 15 minutes per centimetre.
Fixture units: bath group 6.0 + toilet 4.0 + basin 1.5 + kitchen sink 1.5 + dishwasher 1.0 + washing machine 1.5 = 15.5. That is under 20, so there is no fixture unit addition. Floor area is under 200 m², so there is no floor area addition.
Daily design flow: Q = 1,600 L.
Tank: 2 × 1,600 = 3,200 L, which is below the minimum, so the tank must be at least 3,600 L.
Trench length: 1,600 × 15 ÷ 200 = 120 m.
Layout: at a maximum of 30 m per run, 120 ÷ 30 = 4 runs of 30 m. With 1.6 m between centres and 500 mm wide trenches, the four trenches span 3 × 1.6 + 0.5 = 5.3 m. The trench area is therefore about 30 m × 5.3 m (98 ft × 17 ft) before any mantle, clearance or reserve area is added.
Worked example: the same house on slow soil
Now the T-time is 40 minutes per centimetre, typical of a silty soil.
Trench length: 1,600 × 40 ÷ 200 = 320 m, which is 320 ÷ 30 = 10.7, so 11 runs. The trenches span 10 × 1.6 + 0.5 = 16.5 m.
That bed covers roughly 30 m × 16.5 m (98 ft × 54 ft). On many rural lots this does not fit inside the clearances, so a designer would look at a filter bed in imported sand instead. Ontario's worksheet sizes the filter bed's effective area as Q ÷ 75 where Q is 3,000 L/day or less: 1,600 ÷ 75 = 21.3 m². The contact area between the sand and the native soil is Q × T ÷ 850: 1,600 × 40 ÷ 850 = 75.3 m².
The same house needs two and two-thirds times as much trench on slow soil as on loam.
Permits and who can do the work
Ontario
Part 8 of the Ontario Building Code governs on-site sewage systems. A septic tank with a leaching bed is a Class 4 system. A permit is needed before construction, issued by the municipality, health unit or conservation authority that administers Part 8 in your area. The application includes the daily design flow, soil information and the bed calculations shown above.
British Columbia
The Sewerage System Regulation covers systems serving a single-family residence or duplex, and other systems with a combined design daily flow under 22,700 L. Key requirements:
- Only an authorized person may file and certify a system: a registered onsite wastewater practitioner (ROWP), or a professional with training in soil analysis and sewerage systems who is a practising member of a recognized professional association.
- Before construction, the authorized person files the owner's details, the soil type, depth and porosity, sealed plans and specifications, and written assurance that the plans follow standard practice with the regional health authority.
- Within 30 days of finishing, the authorized person gives the owner the plans, a maintenance plan and a letter certifying that the system was built to standard practice and substantially to the filed plans. A copy goes to the health authority.
- Owners must maintain the system according to the maintenance plan and keep maintenance records.
- Systems designed for a daily flow over 9,100 L may be built or maintained only by a professional.
Other provinces and the northern United States
Every province and territory has its own private sewage standard. In the United States, state health or environmental departments set the rules. Before building, ask the local office which permit applies and who may design and install the system. When buying a rural property, ask the same office for the system's permit file, and have the system inspected before you close.
Care and maintenance
Inspection and pumping
The US EPA advises that an average household system be inspected at least every three years, and that systems with mechanical parts, such as treatment units and pump chambers, generally be inspected every year. Household tanks are typically pumped every three to five years. The real interval depends on the tank size, the number of people, the wastewater volume and the amount of solids.
A septic professional measures the sludge and scum layers. EPA guidance is to pump the tank if:
- the bottom of the scum layer is within 150 mm (6 in) of the outlet, or
- the top of the sludge layer is within 300 mm (12 in) of the outlet.
Solids that reach the outlet are carried into the leaching bed and clog the soil, which is why pumping is far cheaper than repair. The EPA's homeowner guide gave routine maintenance at about US$250 to $300 every three to four years, against US$3,000 to $7,000 to repair or replace a failed system; current prices vary widely by region.
What goes down the drain
- Do not flush or drain grease, food scraps, wet wipes, paints, solvents or other toxic chemicals.
- Limit antibacterial soaps, bleach and harsh cleansers, which kill the bacteria the tank relies on.
- Frequent use of a garbage disposal significantly increases sludge and scum and shortens the pumping interval.
Water use
Too much water at once pushes solids out of the tank before they settle and can flood the bed.
- Spread laundry over the week instead of doing several loads in one day.
- Fix leaks promptly. The EPA notes that a single leaking toilet can waste up to 200 US gal (757 L) a day, which is about the whole base design flow Ontario assigns to a one-bedroom house.
- Keep roof downspouts, sump pumps and surface runoff away from the tank and bed.
Protecting the leaching bed
- Keep a sketch of the tank and bed with measurements from fixed points such as house corners.
- Do not drive or park on the tank or bed, and do not build sheds, decks or patios over them.
- Plant only grass over the bed. Keep trees and shrubs well away; roots enter pipes. Ask a septic professional what distance suits the species.
- Fit risers to the tank lids so the tank can be inspected and pumped without digging.
Seasonal cabins and cold weather
Many cabin systems sit unused for months. A septic tank does not need daily use to work, but the pipes and tank must be protected from freezing, and the system must still be reachable for service.
- Pipe slope: the building sewer should fall steadily to the tank with no sags. Water that sits in a low spot freezes and blocks the line.
- Leaks and drips: a slow trickle into a cold pipe can freeze in place before it reaches the tank. Fix dripping taps and running toilets before winter.
- Closing a cabin: follow the drain-down steps in our water systems guide, and use RV antifreeze only in traps and toilet bowls, in the small amounts needed.
- Snow cover: do not plough or pack snow over the tank or bed.
- Access: note how close a pump truck can get in each season and how much hose your local hauler carries. A tank that cannot be reached during spring break-up cannot be pumped when it fails.
Signs of trouble
The EPA lists these warning signs of a failing system:
- wastewater backing up into household drains;
- bright green, spongy grass on the leaching bed, even in dry weather;
- pooling water or muddy soil around the tank, bed or basement;
- a strong odour around the tank or bed.
Slow drains throughout the house and gurgling plumbing are also signs. A single slow fixture is more often a blocked drain or trap in the house. If you suspect a failure, cut water use, call a septic professional and test your well for bacteria.
Key points
- The tank separates solids; the soil under the leaching bed does the treatment, so soil depth and permeability decide what can be built.
- In Ontario, trench bottoms must be at least 900 mm above high groundwater or rock, and conventional trenches are not allowed where the T-time is 50 or more.
- Ontario sizes a three-bedroom house at 1,600 L/day, a tank of at least twice that flow with a 3,600 L minimum, and trench length of Q × T ÷ 200 with runs no longer than 30 m.
- Keep the leaching bed at least 15 m from a cased drilled well and 30 m from other wells under Ontario rules; check your own jurisdiction's figures.
- Use an authorized designer and get the permit: a Part 8 permit in Ontario, and a ROWP or professional filing with the health authority in BC.
- Inspect every three years, pump every three to five years or when scum is within 150 mm or sludge within 300 mm of the outlet.
- Keep grease, wipes and chemicals out, spread water use over the week, and never drive on or enter any part of the system.
This guide is general information. Codes, permits and safety requirements vary by province, state and municipality. Check local rules and use a qualified professional for electrical, gas, chimney and septic work where required.
The Comprehensive Off-Grid Manual
Every off-grid system in one manual, with worked examples, checklists and northern-climate detail.
More guides
Composting Toilets and Greywater Systems
Off-grid toilet options, safe humanure composting and curing, urine use, simple greywater systems, setbacks, cold-climate issues and permits.
Greywater Systems: Rules, Design and Reuse
Greywater rules in BC, Ontario, Alberta, Washington and Oregon: setbacks, leaching pit and irrigation sizing, storage limits and treated toilet-flushing reuse.
Off-Grid Solar Power: How to Size a System