The building envelope is everything that separates heated space from the outdoors: roof, walls, windows, doors, floor and foundation. On an off-grid property every watt lost through it must be replaced with wood, propane or stored electricity. This guide covers how heat leaves a building, insulation values and code levels in Canada and the northern United States, a component-by-component heat-loss calculation, air sealing, vapour control, and the details that matter in attics, walls and foundations.
How heat leaves a building
Heat moves out of a building in three ways.
- Conduction through solid materials: framing, sheathing, glass, concrete. Insulation slows conduction.
- Air leakage: warm air escaping through gaps at the top of the building while cold air enters at the bottom. Natural Resources Canada (NRCan) puts excess air infiltration at about 25% of heat loss in a typical house.
- Radiation: in most houses this accounts for less than 10% of heat loss, mostly through windows.
NRCan also notes that windows and doors can account for up to 25% of a house's heat loss, and basements about 20%. Shares vary widely between buildings, so calculate your own before spending money.
RSI and R-values
Thermal resistance is stated as RSI (metric, in m²·K/W) or R (imperial, in ft²·°F·h/BTU). To convert, divide the R-value by 5.678 to get RSI, or multiply RSI by 5.678 to get R. R-20 is 20 ÷ 5.678 = RSI 3.52.
The heat-flow rate through an assembly, called the U-value, is the inverse: U = 1 ÷ RSI, in W/(m²·K). A wall at RSI 3.52 has a U-value of 1 ÷ 3.52 = 0.28 W/(m²·K), meaning each square metre loses 0.28 W for every degree of difference between inside and outside.
Nominal and effective values
The number printed on a batt is its nominal value. Studs, plates and headers conduct heat far faster than insulation, so the whole wall performs worse than the batt. NRCan gives the example of a 2×6 wall filled with RSI 3.52 (R-20) batts that may have an effective value of only RSI 2.99 (R-17). Canadian energy codes now set requirements in effective values, which account for this framing loss.
Insulation materials
The table lists design values per 25.4 mm (1 in) of thickness from NRCan's Keeping the Heat In. Actual products vary; use the value on the product label or technical data sheet for your own calculations.
| Material | RSI per 25.4 mm (R per inch) |
|---|---|
| Closed-cell polyurethane spray foam | 1.06 (R-6) |
| Extruded polystyrene board (XPS) | 0.88 (R-5) |
| Expanded polystyrene, Type II (EPS) | 0.70 (R-4) |
| High-density glass fibre board | 0.70 (R-4) |
| Expanded polystyrene, Type I (EPS) | 0.67 (R-3.8) |
| Open-cell polyurethane spray foam | 0.63 (R-3.6) |
| Cellulose fibre, blown (settled) | 0.63 (R-3.6) |
| Mineral fibre batt | 0.60 (R-3.4) |
| Glass fibre batt | 0.56 (R-3.2) |
| Glass fibre, loose fill, blown | 0.51 (R-2.9) |
| Softwood logs (other than cedar) | 0.22 (R-1.25) |
| Straw bale | 0.26 (R-1.45) |
A log wall is a poor insulator per unit of thickness: a 200 mm (8 in) softwood log gives about 200 ÷ 25.4 × 0.22 = RSI 1.73 (R-9.8), a little over half the effective value of a 2×6 wall with batts. NRCan advises scepticism toward long-term claims above RSI 1.14 per 25.4 mm (R-6.5 per inch).
Code insulation levels
Canada
Section 9.36 of the National Building Code of Canada (NBC), adopted with variations by the provinces, sets minimum effective insulation for houses by climate zone. Zones are defined by heating degree-days (HDD) below 18 °C.
| NBC climate zone | Heating degree-days |
|---|---|
| Zone 4 | under 3,000 |
| Zone 5 | 3,000 to 3,999 |
| Zone 6 | 4,000 to 4,999 |
| Zone 7A | 5,000 to 5,999 |
| Zone 7B | 6,000 to 6,999 |
| Zone 8 | 7,000 and over |
Requirements differ depending on whether the house has a heat recovery ventilator (HRV). Two examples from published code guidance:
- Zone 4: above-grade walls RSI 2.78 (R-15.8) effective and ceilings below attics RSI 6.91 (R-39.3) effective, with or without an HRV.
- Zone 7A with an HRV: above-grade walls RSI 2.97 (R-16.9) and ceilings below attics RSI 8.67 (R-49.2) effective, with windows at a maximum U-value of 1.6 W/(m²·K).
These are minimums. NRCan's Keeping the Heat In recommends higher nominal levels, rising with climate severity: walls RSI 3.9 to 7.1 (R-22 to R-40), ceilings RSI 7.1 to 10.6 (R-40 to R-60), and floors over unheated space RSI 4.8 to 8.8 (R-27 to R-50). Get exact values for your location from your building authority.
Northern United States
The 2021 International Energy Conservation Code (IECC), adopted with amendments by many states, requires R-60 ceilings in climate zones 5 to 8. Wood-frame walls need R-30 cavity, R-20 cavity plus R-5 continuous, R-13 plus R-10 continuous, or R-20 continuous. Basement walls need R-15 continuous, R-19 cavity or R-13 plus R-5 continuous; slabs need R-10 for 1.2 m (4 ft). Check which edition your state and county enforce.
Calculating heat loss by component
The heat loss of each part of the envelope is its area divided by its RSI, giving watts per degree of temperature difference (W/K). Adding the parts shows where heat goes and which upgrade gives the most benefit.
Component heat loss (W/K) = area (m²) ÷ effective RSI, or area × U-value for windows and doors.
Air leakage is calculated from the volume of air exchanged. Heating 1 m³ of air by 1 °C takes about 0.33 Wh, so:
Air leakage heat loss (W/K) = 0.33 × air changes per hour × heated volume (m³)
Worked example: where a cabin loses its heat
A single-storey cabin measures 8 m × 10 m (26.2 ft × 32.8 ft) with 2.4 m (7.9 ft) walls, over a ventilated crawl space. The design temperature difference is 21 °C inside to −25 °C outside, or 46 °C.
- Floor area: 8 × 10 = 80 m². Volume: 80 × 2.4 = 192 m³.
- Gross wall area: perimeter 36 m × 2.4 m = 86.4 m². Less 14 m² of windows and doors, net wall = 72.4 m².
Assumed effective values: 2×6 walls with batts RSI 2.99; attic RSI 8.67; floor RSI 4.0; windows and doors U = 1.6.
- Walls: 72.4 ÷ 2.99 = 24.2 W/K
- Ceiling: 80 ÷ 8.67 = 9.2 W/K
- Floor: 80 ÷ 4.0 = 20.0 W/K
- Windows and doors: 14 × 1.6 = 22.4 W/K
- Air leakage at an assumed 0.5 air changes per hour: 0.33 × 0.5 × 192 = 31.7 W/K
Total: 24.2 + 9.2 + 20.0 + 22.4 + 31.7 = 107.5 W/K. At the design difference of 46 °C: 107.5 × 46 = 4,945 W, or about 4.9 kW (16,900 BTU/h).
Air leakage is the largest item, followed by windows and doors, which are only 14 m² of the envelope. More attic insulation would save little. Sealing the cabin to 0.1 air changes per hour cuts air leakage loss to 0.33 × 0.1 × 192 = 6.3 W/K, saving 25.4 W/K, or 25.4 × 46 = 1,170 W at design conditions. A building that tight also needs controlled mechanical ventilation, covered in our guide to ventilation and moisture.
Worked example: adding exterior foam to the walls
Adding 38 mm (1.5 in) of XPS outside the sheathing adds 38 ÷ 25.4 × 0.88 = RSI 1.32. The wall rises from RSI 2.99 to 4.31, and wall loss drops from 24.2 to 72.4 ÷ 4.31 = 16.8 W/K, a saving of 7.4 W/K.
At 5,000 heating degree-days, the annual saving is 7.4 × 5,000 × 24 = 888,000 Wh, or about 890 kWh of heat.
Air sealing
Air leakage carries both heat and moisture. NRCan notes that one small air leak can let in 100 times more moisture than diffusion. Moist indoor air leaking into a cold wall or attic condenses and causes rot, mould and attic frost.
The air barrier
The air barrier is the continuous layer that stops air movement. It can be polyethylene, sealed drywall, taped sheathing or house wrap, if it is continuous and supported on both sides. The NBC requires:
- all joints in panel materials to be sealed;
- joints in sheet materials to be sealed, or lapped at least 100 mm (4 in) and clamped between framing and a rigid panel;
- the air barrier to continue across intersections where interior walls and floors meet exterior walls, ceilings and roofs;
- penetrations for doors, windows, wiring, electrical boxes, piping and ducts to be sealed;
- attic access hatches to be weatherstripped;
- gaps around chimneys and gas vents to be sealed with non-combustible material.
Where the leaks are
The common leakage points are the rim joist, basement and upper-storey windows, and holes in the top-floor ceiling for wiring, plumbing stacks, light fixtures and hatches. Seal the top and bottom of the building first, where pressure differences are greatest.
Materials and methods
- Caulking for small joints that do not move. Use backer rod in joints of 6 mm (1/4 in) or wider before caulking. Use non-combustible caulking near heat sources.
- Tape and gaskets for sheet and panel joints, and gaskets for electrical boxes on exterior walls.
- One-part spray foam for larger gaps around pipes, wiring and window frames.
- Weatherstripping for joints that move, such as doors, operable windows and hatches.
Ventilate while interior sealants cure, typically two or three days, and for 24 to 48 hours after spray foam.
Testing airtightness
A blower door test depressurizes the house to 50 Pa and measures leakage in air changes per hour at that pressure (ACH50). Test before work to find leaks and after to confirm results. Published targets:
| Program or level | Maximum ACH50 |
|---|---|
| BC Energy Step Code, Step 2 | 3.0 |
| BC Energy Step Code, Step 3 | 2.5 |
| R-2000 Standard; BC Energy Step Code, Step 4 | 1.5 |
| BC Energy Step Code, Step 5 | 1.0 |
Vapour control
Water vapour also moves through materials by diffusion, from warm, humid indoor air toward the cold outside. A vapour barrier on the warm side of the insulation slows this. Under the NBC, a vapour barrier must have a permeance of no more than 60 ng/(Pa·s·m²). Polyethylene, foil, some paints and some vinyl wall coverings meet this; polyethylene is commonly installed at 0.15 mm (6 mil) and should conform to the CGSB standard, with lapped, sealed joints over framing.
House wrap is an air barrier and drainage layer, not a vapour barrier.
The one-third rule
A vapour barrier can sit partway into a wall, behind a service cavity for wiring, if no more than one third of the insulating value lies on its warm side. NRCan recommends reducing this to one quarter or less in very cold climates or where indoor humidity is high.
Exterior foam and the outboard ratio
Foam boards and foil-faced products on the outside of a wall are themselves low-permeance layers. If they are too thin, the inner face of the foam stays cold enough for vapour to condense on it inside the wall. The NBC sets a minimum ratio of insulating value outboard of that inner face to insulating value inboard of it:
| Heating degree-days | Minimum ratio, outboard to inboard |
|---|---|
| Up to 4,999 | 0.20 |
| 5,000 to 5,999 | 0.30 |
| 6,000 to 6,999 | 0.35 |
| 7,000 to 7,999 | 0.40 |
| 8,000 to 8,999 | 0.50 |
| 9,000 to 9,999 | 0.55 |
| 10,000 to 10,999 | 0.60 |
| 11,000 to 11,999 | 0.65 |
| 12,000 or higher | 0.75 |
Worked example: how thick must exterior foam be?
A 2×6 wall has RSI 3.52 (R-20) batts in the cavity. The site has 6,500 heating degree-days, so the ratio is 0.35.
Required outboard RSI: 0.35 × 3.52 = 1.23 (counting only the batts inboard, which gives a slightly conservative result).
XPS at RSI 0.88 per 25.4 mm needs 1.23 ÷ 0.88 × 25.4 = 35.5 mm. Use 38 mm (1.5 in) board, which gives RSI 1.32.
At 4,500 HDD the wall needs 0.20 × 3.52 = 0.70, or 20.3 mm of XPS, so 25 mm (1 in) board meets it. Thin foam such as 13 mm (1/2 in) fails the ratio in a cold climate.
Attics, roofs and walls
Attics
Blown loose fill is the cheapest way to reach high attic values. Seal every ceiling penetration from above first; insulation does not stop air.
- Ventilation: NRCan recommends about 1 unit of unobstructed vent area per 300 units of ceiling area, split evenly between continuous soffit vents and roof, ridge or gable vents. Screens and baffles reduce free area, so allow more.
- Baffles: install them at each rafter space at the eaves to keep 38 to 50 mm (1.5 to 2 in) of air space between the insulation and the roof sheathing.
- Eaves: where low roofs restrict insulation at the eaves to about 100 mm (4 in), the cold ceiling edge and warm roof above encourage ice dams. Higher-value insulation at the eaves, or a raised-heel truss on new work, reduces this.
- Chimneys: keep insulation at least 75 mm (3 in) from a metal chimney unless the manufacturer or local authority specifies otherwise, and build a barrier 75 mm (3 in) from a masonry chimney face, extending at least 75 mm above the insulation.
Walls
Closed cavities in older walls can be filled with dense-pack cellulose blown at about 56 to 72 kg/m³ (3.5 to 4.5 lb/cu ft), which resists settling and slows air movement. New walls can add exterior foam or mineral fibre board, which cuts framing heat loss and keeps the sheathing warmer. Spray foam must be applied by a certified installer.
Foundations, floors and crawl spaces
Basements
Basement insulation can go outside or inside the foundation wall.
- Outside: keeps the concrete warm and dry and protects it from frost. NRCan's minimum is insulation extending at least 600 mm (24 in) below grade, with an optional horizontal skirt of 600 mm. Protect the above-grade portion with a covering that extends about 300 mm (12 in) below ground. Excavate to the footings but never below them.
- Inside: rigid board of at least RSI 2.1 (R-12), unless the code requires more, covered with 12.7 mm (1/2 in) drywall. First tape a 1 m (40 in) square of polyethylene to the concrete; water under it after a day or two means drainage must be fixed before insulating.
- Rubble and stone walls: limit batt or closed-cell foam on the inside to about RSI 2.1 (R-12), so the wall stays warm enough to dry.
Drainage and grading
Slope the ground away from the building by about 10%, or 200 mm over the first 2 m (8 in over 6 ft), and direct downspouts at least 2 m (6 ft) from the foundation.
Rim joists
Cut-and-fit rigid board sealed at the edges, or closed-cell spray foam at least 50 mm (2 in) thick, insulates and air-seals the rim joist.
Floors over crawl spaces
Many cabins sit on piers or a ventilated crawl space with an insulated floor above. Fill the floor cavity and add a sealed air barrier so cold air does not wash through the insulation. Pipes below then sit outside the heated envelope and need freeze protection. The alternative is to insulate and air-seal the crawl space walls, bringing the crawl space inside the envelope.
Windows and doors
NRCan notes that single glazing loses 10 to 20 times as much heat as the same area of well-insulated wall, and that a storm window or double glazing cuts that loss by almost half.
- Choose windows by their rated U-value. In NBC climate zone 7A the code maximum is 1.6 W/(m²·K); lower is better.
- Low-emissivity coatings, gas fill and insulated spacers cut heat loss and keep the inner glass warmer.
- Seal the gap between the window frame and the rough opening to the wall's air barrier with low-expansion foam or backer rod and sealant, and flash the opening to shed water.
Permits and safety
- Permits: new construction, additions and many renovations need a building permit where building inspection applies, and changes to insulation can trigger the energy requirements of the code. Electrical upgrades need an electrical permit. Check with your municipality or regional district before starting.
- Energy advisor: an NRCan-certified energy advisor can model the house and run blower door tests.
- Combustion appliances: in a tight house, exhaust fans can pull combustion gases back down the chimney of a stove, furnace or water heater. Have fuel-burning appliances checked after major air sealing, and install carbon monoxide alarms near them and near sleeping areas.
Key points
- RSI = R ÷ 5.678. Heat loss of each component is area ÷ effective RSI, in W/K; air leakage is 0.33 × air changes per hour × volume.
- Framing reduces a wall's performance: a 2×6 wall with R-20 batts may be only about R-17 effective.
- Canadian code minimums depend on the NBC climate zone, set by heating degree-days, and on whether an HRV is installed.
- The air barrier must be continuous, with sealed joints, penetrations and intersections. Seal leaks at the top and bottom of the building first.
- A vapour barrier must be no more than 60 ng/(Pa·s·m²) and sit on the warm side, with at least two thirds of the insulating value outboard of it.
- Exterior foam must be thick enough to meet the NBC outboard-to-inboard ratio for your heating degree-days.
- Keep foundations dry with grading and drainage, insulate rim joists, and cover foam with a thermal barrier.
- Get permits where required, have combustion appliances checked after air sealing, and leave suspect vermiculite undisturbed.
This guide is general information. Codes, permits and safety requirements vary by province, state and municipality. Check local rules and use a qualified professional for electrical, gas, chimney and septic work where required.
The Comprehensive Off-Grid Manual
Every off-grid system in one manual, with worked examples, checklists and northern-climate detail.
More guides
Site Work, Drainage and Foundations in Frost Country
How frost heave works, reading soil, site preparation and drainage, code footing depths and sizes, piers, screw piles, insulated foundations and cold concrete.
Ventilation, Moisture and Indoor Air in a Tight Off-Grid Home
Control indoor humidity and condensation in a tight off-grid home: moisture sources, ventilation rates, HRV and ERV heat savings, backdraft safety and radon.
Off-Grid Solar Power: How to Size a System
Size an off-grid solar system for Canadian winters: load audit, peak sun hours, array, MPPT, inverter, wiring, fusing, with a full cabin example.