Ventilation, Moisture and Indoor Air in a Tight Off-Grid Home

Shelter  13 min read

A well-sealed, well-insulated building saves fuel, but it no longer replaces its air through leaks. Moisture from people, cooking and bathing, along with combustion gases and indoor pollutants, stays inside unless it is removed on purpose. This guide covers where indoor moisture comes from, how much humidity a building can hold in a Canadian winter before windows and walls get wet, how much fresh air a home needs, the heat cost of ventilation and how heat recovery reduces it, system types, combustion safety, crawl spaces, seasonal cabins and radon.

Why a tight building needs ventilation

An older, leaky house is ventilated by accident. Wind and the stack effect push outdoor air in low down and let warm, moist air out near the top, too much on cold, windy days and too little on calm ones. The leaking air carries moisture into walls and attics.

Air sealing stops that, which is good for heating costs and for the structure. A house built to the R-2000 Standard leaks no more than 1.5 air changes per hour at 50 Pa, and some builders now reach 1.0 or less. At those levels the natural air exchange is far below what occupants need, so ventilation must be supplied by fans. Our guide to insulation and the building envelope covers air sealing; this guide covers what to do once a building is tight.

Ventilation removes:

  • water vapour from breathing, cooking, bathing, laundry and plants;
  • carbon dioxide and odours from occupants;
  • gases released by new materials, finishes, furniture and cleaning products;
  • smoke and fine particles from cooking and from opening a wood stove door;
  • radon and other soil gases that enter through the foundation.

Where indoor moisture comes from

NRCan's Keeping the Heat In estimates that a family of four produces about 50 L (13 US gal) of water vapour per week from normal activities, or about 7 L per day. Several sources common on rural and off-grid properties add to that:

  • Firewood drying indoors: wood that is not fully seasoned gives off its remaining water into the house. Keep the main woodpile outdoors or in an unheated shed and bring in only a day or two of dry wood at a time.
  • Clothes drying indoors: common where an electric dryer would overload the solar system. A full load of spun laundry releases its water into the room as it dries.
  • Unvented fuel-burning heaters: burning propane or kerosene produces water vapour along with carbon dioxide. A vented appliance sends it outdoors; an unvented one releases it into the room.
  • New construction: fresh concrete and framing lumber release water through the first heating seasons.
  • Wet foundations and crawl spaces: moisture from the ground or from water leaking through foundation walls rises into the house.

Worked example: moisture from an unvented propane heater

Propane (C3H8) burns to carbon dioxide and water: each kilogram of propane produces about 1.63 kg of water. Liquid propane weighs about 0.51 kg per litre, so each litre burned releases about 0.51 × 1.63 = 0.83 kg (0.83 L) of water.

A heater delivering 3 kW for 8 hours produces 3 × 8 = 24 kWh, or 24 × 3.6 = 86.4 MJ. At 25.3 MJ per litre, it burns 86.4 ÷ 25.3 = 3.4 L of propane and releases 3.4 × 0.83 = 2.8 kg of water into the room.

That is about 40% of the 7 L a family of four produces in a day, added by one heater in one evening. It is why unvented heaters cause condensation, mould and peeling paint in small, tight cabins, apart from the risk of carbon monoxide.

Humidity, dew point and condensation

Relative humidity (RH) is the amount of water vapour in air as a percentage of the most it can hold at that temperature. Warm air holds more than cold air. When air cools to the temperature at which its RH reaches 100%, called the dew point, water condenses on the cold surface. In a heated building in winter the cold surfaces are windows, window frames, outside corners, closets on exterior walls, and anywhere insulation is missing.

NRCan gives these thresholds for indoor humidity:

  • above 20% helps prevent a dry, sore throat;
  • above 40% can cause window frosting and fogging, staining, peeling paint and mould;
  • above 50%, airborne diseases become harder to control.

The colder it is outdoors, the colder the inside surface of each window, and the lower the humidity a house can carry without condensation. NRCan's figures for a house kept at 20 °C (68 °F):

Outdoor temperatureMaximum RH, standard windowsMaximum RH, energy-efficient windows
0 °C (32 °F)50%68%
−10 °C (14 °F)38%50%
−20 °C (−4 °F)26%40%
−30 °C (−22 °F)18%30%
−40 °C (−40 °F)12%20%

Keep a hygrometer (digital humidity meter) in the main living area and another in the coldest bedroom. Condensation on the inside of windows is the cue to increase ventilation or reduce moisture sources.

How much fresh air a home needs

NRCan's guidance is that ventilation should change the total household air about once every three hours, which is one third of an air change per hour, with combustion air for fuel-burning appliances supplied separately. In Canada, mechanical ventilation in houses is governed by Section 9.32 of the National Building Code, as adopted by each province. NRCan's R-2000 documentation notes that a system meeting the CSA F326 standard for residential mechanical ventilation also meets Section 9.32. The R-2000 Standard requires systems to be designed, installed and balanced to CSA F326 by an HRAI-certified designer or installer, with HVI-certified fans and ventilators.

Worked example: a ventilation rate for a small house

A house has 150 m² (1,615 sq ft) of heated floor area with 2.4 m (7.9 ft) ceilings.

Heated volume: 150 × 2.4 = 360 m³ (12,700 cu ft).

One third of an air change per hour: 360 ÷ 3 = 120 m³/h. Dividing by 3.6 converts m³/h to litres per second: 120 ÷ 3.6 = 33 L/s (71 cfm).

A code designer will calculate the required rate from the code tables for your house, which can differ from this figure, but it gives the scale of the system: a ventilator moving roughly 30 to 40 L/s continuously, with higher boost rates for bathrooms and cooking.

How ventilation controls humidity

Cold outdoor air holds little water. When it is brought inside and warmed, its relative humidity falls sharply, and as it replaces indoor air it carries moisture out. The colder the weather, the more water each cubic metre removes.

The maximum water air can hold at each temperature is a physical constant: about 17.3 g/m³ at 20 °C, 4.8 g/m³ at 0 °C and 2.1 g/m³ at −10 °C.

Worked example: what indoor humidity will ventilation produce?

The house above is ventilated at 120 m³/h, or 120 × 24 = 2,880 m³ per day. Four people produce about 7.1 kg (7,100 g) of water vapour a day.

When moisture added equals moisture removed, indoor water content settles at:

indoor content = outdoor content + daily moisture ÷ daily air volume

At −10 °C outdoors, with outdoor air near saturation at 2.1 g/m³: 2.1 + 7,100 ÷ 2,880 = 2.1 + 2.5 = 4.6 g/m³. At 20 °C indoors that is 4.6 ÷ 17.3 = 27% RH.

At 0 °C outdoors, with outdoor air at 4.8 g/m³: 4.8 + 2.5 = 7.3 g/m³, or 7.3 ÷ 17.3 = 42% RH.

At 0 °C the house is near the 40% level where condensation starts, so the full ventilation rate is needed. At −10 °C and colder the same rate dries the house to below 30%, and turning the ventilation down, or using an energy recovery ventilator that returns some moisture, keeps conditions more comfortable. Ventilation rates need adjusting through the season, which is why controls with humidity sensing are useful.

The heat cost of ventilation

Every cubic metre of outdoor air brought in must be heated. Heating 1 m³ of air by 1 °C takes about 0.33 Wh.

Ventilation heat loss (W) = 0.33 × airflow (m³/h) × temperature difference (°C)

A heat recovery ventilator (HRV) passes outgoing stale air and incoming fresh air through a core where heat moves from one stream to the other without the air mixing. NRCan states that HRVs typically recover about 70% of the heat in the exhaust air.

Worked example: heat saved by an HRV

The house ventilates at 120 m³/h. At 20 °C inside and −10 °C outside, the difference is 30 °C.

Without heat recovery: 0.33 × 120 × 30 = 1,188 W, or about 1.2 kW of heating used only to warm ventilation air.

With an HRV recovering 70%: 1,188 × (1 − 0.70) = 356 W.

Over a heating season at a location with 5,000 heating degree-days: 0.33 × 120 × 5,000 × 24 = 4,752,000 Wh, or about 4,750 kWh without recovery. The HRV saves about 0.70 × 4,750 = 3,325 kWh of heat, which is about 12 GJ. That is roughly 510 L of propane in a 92% furnace, or a little over half a cord of hardwood in a stove delivering 70% of the wood's energy.

Fan power on an off-grid system

An HRV or ERV runs two fans around the clock, so its electrical draw is a continuous load on the battery bank. Read the rated wattage at the intended airflow from the manufacturer's HVI-certified data. A unit drawing 50 W continuously uses 50 × 24 = 1.2 kWh per day. Compare that with the heat it saves (about 9 kWh of heat per day on average in the example above) and with your winter solar budget, as set out in our solar power guide. Units with electronically commutated (ECM) fan motors use less power.

Types of ventilation system

Exhaust-only

Bathroom fans and a range hood ducted outdoors remove moisture at its source, and air leaks in to replace it. Exhaust-only systems are cheap, but they put the house under slight negative pressure, which in a tight house can pull combustion gases down a chimney and draw soil gas through the foundation. Duct them outside, never into an attic.

Supply-only

A fan pushes filtered outdoor air into the house and stale air leaks out. In a cold climate this drives warm, moist air into the walls and ceiling, where it can condense, so supply-only systems suit tight northern buildings poorly.

Balanced: HRV and ERV

Balanced systems supply and exhaust equal amounts of air, keeping house pressure neutral. An HRV transfers heat only. An energy recovery ventilator (ERV) also transfers some water vapour from the exhaust to the supply air. Choose an HRV where the main winter problem is excess humidity, such as a small, busy house or one with indoor laundry drying. Consider an ERV where winter air is very dry, as the example above shows it can be below −10 °C, provided indoor humidity stays below the window condensation limits.

In deep cold, the core of either unit can freeze as moisture from the exhaust air condenses and turns to ice. Units sold for cold climates have a defrost cycle; check its operating range against your design temperature.

Installation points

  • Insulate ducts carrying outdoor air through heated space to at least RSI 0.5 (R-3) and cover them with a sealed vapour barrier; R-2000 requires this, and it stops condensation dripping from the duct.
  • Place the fresh-air intake away from the exhaust hood, vehicle parking, fuel tanks, dryer vents and chimney discharge, and above expected snow depth.
  • Run the condensate drain to a trapped drain or a heated location so it cannot freeze.
  • Have the system balanced after installation so supply and exhaust flows match. R-2000 calls for filters of MERV 13 where filtration applies.
  • Clean or replace filters and clean the core on the schedule in the manual. A clogged filter cuts airflow and the system then no longer ventilates as designed.

Combustion appliances in a tight house

A naturally drafting appliance, such as a wood stove, an older oil furnace or a water heater vented into a chimney, relies on warm flue gases rising up the chimney. If exhaust fans lower the pressure in the house, outdoor air can be pulled down the chimney instead, bringing smoke and carbon monoxide into the house. This is called backdrafting or spillage.

  • Choose sealed-combustion (direct-vent) appliances for tight buildings; they take combustion air from outdoors through a pipe and are not affected by house pressure.
  • Where a wood stove or other open-combustion appliance remains, give it an outdoor combustion air supply where the manufacturer allows one, and avoid running a large range hood or several exhaust fans while it is burning.
  • Large range hoods can exhaust more air than leaks can replace in a tight house; a makeup air supply may be required. Ask the installer or building official.
  • Before a blower door test, NRCan advises turning off fuel-fired space and water heaters so the test does not backdraft them.
  • Do not use unvented fuel-burning heaters as a regular heat source in a tight building.

Crawl spaces and foundations

Bare soil under a building releases a steady flow of water vapour. In a crawl space, NRCan recommends a ground moisture barrier of at least 0.10 mm (4 mil) polyethylene, overlapped and taped at the joints. For a vented crawl space, NRCan suggests vent area of about 1 unit per 500 units of floor area, open in spring and closed in winter. Keep downspouts and grading directing water away from the foundation; a crawl space with standing water cannot be kept dry by ventilation.

Heavy frost on the underside of the roof sheathing in winter usually means warm, moist house air is leaking into the attic. Seal the ceiling leaks first; adding more attic vents does not cure an air leak.

Seasonal and intermittently used cabins

A cabin closed for weeks or months has no heat or ventilation. Common problems are musty odours, mould on cold walls and closets, and condensation when it is reopened and warmed quickly.

  • Before closing, remove moisture sources: wet towels and clothing, open food, houseplants and water left in buckets or kettles. Leave interior doors, closets and cupboards open so air can circulate.
  • On arrival, open windows and run the ventilation system or exhaust fans while the building warms, so moisture released from surfaces leaves rather than condensing.
  • If the cabin is kept heated in winter, leave the HRV or a low-speed exhaust fan running on a timer or humidity control, set to keep humidity within the window limits in the table above.

Radon

Radon is a radioactive gas produced by the natural breakdown of uranium in soil and rock. It enters buildings through foundation cracks, floor drains, sumps and gaps around pipes, and builds up most in basements and lower floors, especially in winter when the house is closed and the stack effect draws soil gas in. It has no colour, smell or taste; long-term exposure increases the risk of lung cancer.

  • The only way to know the level in a building is to test. Use a long-term test kit placed in the lowest regularly occupied level during the heating season, following the kit instructions, and compare the result with the Health Canada guideline or, in the United States, the EPA action level.
  • Air sealing and depressurizing exhaust systems can change radon levels, so test again after major envelope work.
  • Where levels are high, the usual fix is sub-slab depressurization: a pipe and small fan draw soil gas from beneath the slab and vent it above the roof. Use a certified radon mitigation professional.
  • Building codes include soil gas control requirements for new houses. Ask your building official what applies locally before pouring a slab.

Mould

Mould grows where surfaces stay damp: window frames with constant condensation, cold exterior corners behind furniture, bathroom ceilings, and walls or floors wetted by leaks. Removing the moisture source is the only lasting fix; cleaning alone fails if the surface keeps getting wet.

  • Clean small areas on hard surfaces with water and dish detergent, wearing gloves, eye protection and a disposable dust mask, then dry the area completely.
  • Discard mouldy porous materials such as ceiling tiles, carpet and insulation.
  • For large areas, or mould inside walls or ducts, use a qualified remediation contractor.

Key points

  • A tight building needs mechanical ventilation. NRCan's guideline is about one third of the house air replaced each hour; code design follows NBC Section 9.32 or CSA F326.
  • A family of four produces about 50 L of water vapour a week. Indoor firewood, laundry drying and unvented heaters add much more.
  • Keep humidity below the window condensation limit for the outdoor temperature: at 20 °C inside and −20 °C outside, about 26% with standard windows and 40% with energy-efficient ones.
  • Ventilation heat loss is 0.33 × m³/h × °C. An HRV recovers about 70% of it.
  • Below about −10 °C, normal ventilation can over-dry a house; reduce the rate or use an ERV.
  • Exhaust-only systems and large range hoods can backdraft open-combustion appliances. Use sealed-combustion appliances in tight buildings and install CO alarms near bedrooms.
  • Put a 4 mil or heavier polyethylene ground cover in crawl spaces, test for radon in the heating season, and fix the moisture source before cleaning mould.

This guide is general information. Codes, permits and safety requirements vary by province, state and municipality. Check local rules and use a qualified professional for electrical, gas, chimney and septic work where required.